JME Engineering Guides · Solar batteries and backup

Solar Battery Backup and Runtime in Pakistan

Quick answer. A 5.12 kWh solar battery can support a steady 1 kW load for about 3.2 hours during a WAPDA outage if it starts at 90% charge, stops at a 20% reserve and delivers energy at 90% DC-to-AC efficiency. This estimate assumes no solar input. Divide the energy available to your AC loads by their average demand in kW, then check that the battery and inverter can handle peak demand.

Published by JME Energy & Automation ·

How to estimate battery backup hours

Use the manufacturer’s energy rating and your measured essential load. The units matter.
InputWhat to use
Energy available from the battery (kWh)If you start with nominal capacity, multiply it by the difference between starting and minimum allowed state of charge. For 90% down to a 20% reserve, that is a 70% window. If the manufacturer gives usable energy for the same window, use that value directly.
Energy delivered to AC loads (kWh)Apply an estimated discharge conversion efficiency if your figure is DC-side energy. If the quoted figure is already usable AC energy for that window, use it directly.
Average and peak essential load (kW)Divide the usable AC energy by average essential load for a rough runtime. Separately verify the continuous and surge ratings of the battery and inverter against peak load.
Solar contribution during outagesUse zero solar for a conservative nighttime estimate. During daylight, count solar only if the system is designed to keep the relevant PV running in backup mode. Output varies with weather and time.

Example. Illustrative 5.12 kWh battery, starting at 90% with a 20% reserve and assumed 90% DC-to-AC discharge efficiency. 5.12 × 0.70 × 0.90 gives about 3.23 kWh for AC loads. At a steady 1 kW, that is about 3.2 hours without solar. Actual runtime also depends on temperature, battery condition, inverter standby consumption, and load changes.

Commercial backup example. A shop or small office with a steady 4 kW of essential loads and a nominal 20 kWh battery could get about 3.2 hours of nighttime backup. This assumes a 90% starting charge, a 20% reserve and 92% DC-to-AC discharge efficiency (20 × 0.70 × 0.92 ÷ 4). Measure the actual load and check the inverter and battery ratings for compressor or motor startup before sizing the system.

Check these details before buying

  1. List the circuits that must stay on and measure their typical load during the hours you need backup.
  2. Write down the minimum backup time, expected starting charge, and minimum reserve.
  3. Check the exact inverter and battery combination, including continuous output and starting loads such as pumps or compressors.
  4. For an industrial site, model demand from a load profile and check how the BESS, solar, generator and grid are expected to operate during transfer.

Common questions

How long will a 5 kWh battery run a 1 kW load?

Five hours is the simple estimate only when 5 kWh is actually available at the AC loads. A 5 kWh nominal battery usually delivers less over the chosen charge window after losses.

What is the difference between battery kWh and inverter kW?

Battery kWh describes stored energy. Inverter kW describes the rate of power delivery. Check both when choosing a system.

Do I size the battery from the solar panel capacity?

Size backup energy around the essential load and the hours it must run. Use solar production to assess whether and when the battery can recharge.

Can solar recharge the battery during load shedding?

It can if the system supports solar generation and battery charging in backup mode. Verify that the exact inverter, battery and PV arrangement support that operation.

Can a larger battery fix an inverter overload?

A larger battery adds energy or may improve battery discharge capability, depending on the design. The inverter still has its own output and surge limits.

Use JME’s tools for a site estimate

Use the BESS Backup Runtime Calculator to compare load, starting charge and reserve. For plants with existing generators, the BESS Knowledge Hub explains how backup, peak shaving and solar integration affect the design.

Technical references · NREL fundamentals of energy storage · U.S. Department of Energy guide to solar and resilience.